For gas sampling up to 2,4 m³/h.
Dimensions: ~ 340 x 340, high: ~ 450 mm, weight ~14 kg. The pump starts manually.
In carrying system (transportation frame, material: Stainless Steel-square-tube 15 x 15 mm with handle) are:
- dry gas volume meter (0,04 .. 6 m³/h, accuracy 2% with certificate) with thermometer (0..60°C, scale 1°C) (A)
- rotameter 0,2 .. 2,5 m³/h (scale 0,1 m³/h standard condition) (A).
- dry running rotary vane vacuum pump (performance: 3 m³/h, vacuum: 800 mbar, 230 V/ 0,12 kW) (B)
- Stainless Steel regulation valve (B).
- drying tower (material: PVC, dimensions: Ø 75 mm x 400 mm), space for silicagel: 0,7 l, volume water separator: ca. 0,5 l (C).
- pulsation dumper with filter behind pump (D).
Small drying tower
Size comparable to 250ml impinger
3-parts: bottom, tube and cover
Dimensions Ø50/60mm x height 225mm
Entry and exit thread G1/8"
Hose nipple 6mm or others on request
Cover Ø60mm
Tube Ø50mm x 185mm. Internal diameter Ø40mm
Materials: PVC and plexiglass
Gooseneck with 5 different interchangeable nozzles according to EN 13284-1 and ISO 9096 Nozzle diameters 6, 8, 10, 12, 14 mm, other openings are available on request Thread G1/2, G3/4, M16 or other threads on request Material: stainless steel or titanium Also on Monel® available.
Also possible as 90° bent instead of gooseneck.
The large heater serves filter devices with gas distributor. The heater is fastened to the suction tube by means of a flange and stabilizes the internal parts. At the back of the heater can be mounted a carrying box for bubblers.
Can also be made in special versions or according to your request. E.g. for a 90mm or 110mm filter device (glass), see pictures.
Double temperature controller for probe and filter heater
Total power 3650W, 230V/50Hz.
Main power switch
Double controller circuit.
Connections: standard NiCrNi socket + Europlug (earthed)
Operating voltage: 230V/50Hz
Switching power: max. 3650Watt ohmsche load
Electrical protection class: I
protection type: IP 20
rule behavior: PID; regulator- accuracy 0,5%
sensor breach security: yes
sensor type: NiCr-Ni; Typ K
sensor connection: Thermocouple Connector Typ K
consumer connection: Schuko power outlet max. 16A ohmsche load
Total outlet power no more than 16A ohmsche load.
network connection: power cable with Schuko power connector 1,5mm²
main switch illuminates: 2-pole
housing:plastic ABS and PC
Dimensions: 160x166x134mm (BxHxT)
Ambient temperature: 0 - 50°C
scarf cable gear: relay 16A ohmsche load
LED-display
EMV-compatibility: EN 61326
Interference Stability: industry request
Safety instructions: DIN EN 60204, EN 61010, BGV A3
Jumatherm is a MARKUS DE VRIES brand.
Holder to fix the sampling probe at the measuring point
Choice between Quick fastener holder or gastight-holder
With thread G3" to mount in universal flange or standard threaded flange e.g. DN80, DN100
Threaded flanges also in aluminum available!
Camlock quick couplings for fixation of probes at measuring points
Drying tower model ‘Ströhlein' with integrated condensate trap
Threaded or classic push-on version
Material: PVC / plexiglass
Exterior dimensions Ø100 x 480mm
Silicagel content Ø80 x 370mm
Condensate content ~100ml
Connection G1/2"i
Various hose connections and quick coupllings are possible, most used are quick connects 13mm (see picture)
Material: PVC grey / clear
Two threads in the cover. With a little change, it can be changed to a water separator.
With handle.
Dimensions Ø 160 x 400 mm
Weight: ~ 6 kg,
Water separator: Ø 150 x 65 mm (~1,2 l)
Volume drying agent: Ø 150 x 300 mm
(~ 5,3 l / ~ 4,3 kg silica-gel ≅ 1060 g H2O-adsorption)
Heated box for 90mm glass filter holder.
Also in long version to heat both filter holder and gas distributor.
Fits to all probes