Tethys instrumens EXM500 online ammonia (NH3) analyser
- extractive
- measuring principle UV-spectroscopy
- internal gas circuit heated at 190°C
- no sample cooler required
- 19" rack model, 5U
- Mulitgas configuration possible: NH3, NO, NO2, SO2, H2S, CS2, C6H6, C8H10, NCl3
Housing 3HE 360mm , 2 seperate circuits 230V/16A with on/off switch
- 1x AX4 with Solid-state relais and 5-pin Binder plug at the back (for ~30m heated hose)
- 2x AX4 with 2x solid-state relais and 2x 7-pins binder plug achteraan (for max.10m heated hose)
Connection for both short and lang heated hoses (up to 35m)
Both 5pins and 7pins plug present, though only one heated hose can be connected at the same time
Total power 3650W, 230V/50Hz.
With main power switch, PID temperature control
Operating voltage: 230V/50Hz
Switching power: max. 3650Watt ohmsche load
rule behavior: PID; regulator- accuracy 0,5%
sensor breach security: yes
sensor type: Pt100
Total outlet power no more than 16A load.
network connection: power cable with Schuko power connector 1,5mm²
main switch illuminates: 2-pole
housing:plastic ABS and PC
Dimensions: 160x166x134mm (BxHxT)
Ambient temperature: 0 - 50°C
LED-display
EMV-compatibility: EN 61326
Interference Stability: industry request
Safety instructions: DIN EN 60204, EN 61010, BGV A3
Jumatherm is a MARKUS DE VRIES brand.
Beheizte Sonde mit fest angeschlossenem Digitalregler (JUMO).
Integrierte und beheizte Edelstahlfilterbuchse für kleine Rohrfilter oder Glaswollefilter
Einstellbare Temperatur 0 - 350°C
Material: Edelstahl
Länge 1m, 2m oder andere Längen auf Anfrage
Auf Anfrage mit Harting-Stecker oder Binder-Stecker für externen Temperaturregler
Durchmesser 30 mm
Eingang G1/2" Innengewinde oder G3/8" Innengewinde in Einschraubstück
Ausgang G1/2" Innengewinde
230V/50Hz Netzteil mit 1,5m Netzkabel
Temperaturfühler Pt100
Heizband Textilglas isoliert
Maximale Temperatur 350°C
Leistung ca. 250 W / m
Portable FID analyzer model OVF-3000 by J.U.M. Engineering
- Lightweight internal fuel storage, easy to operate
- Fully heated to 180°C
- Typical sensitivity 0.01 ppm CH4
- Internal sample pump and air pump
- Internal combustion air supply (No external air cylinder needed)
- Disposable sample filter in front panel
- Automatic flame out alarm contact and fuel shut off
- Sample pressure regulator not in contact with sample gas
- Multiple range capability; 5 selectable ranges are standard
Applications
- Stack gas emissions and all other Environmental and process applications
- Air and gas scrubber efficiency
- Process chemical gas analysis
- Personnel safety
- Solvent recovery
- Catalytic converter and thermal combustor testing
- Automotive and engine emissions
- Fence line (perimeter) monitoring
Complies analytically with EN 12619, EN 14181/ EN ISO 14956, (EU) and with EPA Method
25A and Method 503 (USA)
Method | Heated Flame Ionization Detector (HFID) |
Sensitivity | Max. 1 ppm CH4 full scale (100 ppb lowest detectable) |
Response time | @ sample inlet <0.2 seconds |
t90 time | @ sample inlet <1.2 seconds |
t90 time including 4X6mm sample line | Including heated sample line (7.5m) and sample probe filter: less than 8 seconds |
Zero drift | <2% full scale / 24h |
Span drift | <2% full scale / 24h |
Linearity | Up to 10.000 ppm full scale within 1.5% |
Oxygen synergism | < 2% FSD |
Measuring ranges (ppm) | Front panel turn switch: 0-10,100, 1.000, 10.000, 100.000, others on request. |
Signal outputs | 0-10 VDC, 4-20 mA, including RS-232 data output |
Display | 6- digit direct reading ppm units capability to measure up to three (3) overlapping measuring ranges without range change |
Total sample flow through | 2.5 to 2.8 l/min capacity @ operating temp. |
Sample filter | Disposable change filter in rear panel. Option OVE 32 |
Zero and Span gas | Front panel switch selectable and remote control, gas inlets on rear panel |
Zero and span adjust | Manual duo dial on front panel |
Fuel gas | 100% H2, consumption approx. 20 ml/min |
Burner air consumption | Built in burner air supply. No external cylinder air needed. consumption approximately 130 ml/min, all mixed fuel gases approx. 220 ml/min |
Oven temperature | 180°C (374°F) |
Temperature control | micro-processor PID controller |
Power requirements | 230VAC/50Hz, 850W (120 VAC/60Hz optional) |
Ambient temperature | 5-43°C (41-110°F) |
Dimensions | (W x D x H) 445 mm x 220 mm x 350 mm |
Weight | approx. 13 kg |
Attachments
Datalogging
To log the 0-10V and/or 4...20mA analog outputs.
PC-powered: Over USB Software-based J.U.M. MhcLog-109 (dual channel)
Hand held battery powered: Ahlborn ALMEMO 2590
Heated prefilter model VE112 by J.U.M. Engineering.
1 Heated sample inlet
2µm stainless steel sampler filter
5 'hot' outlets for gas cooler, FID, FTIR
Integrated heated sample pump 12l/min
Ideal for stationairy or transportable CEM's (Continuous Emission Monitoring system)
Weight | Approx. 25kg (55 lbs) |
Dimensions (W x D x H) | 19" (483 mm) x 460 mm x 221 mm |
Sample filter material | All stainless steel 316SS |
Filter pore size | 2μm |
Sample valves | All stainless steel/Viton® |
Purge air valve | All brass, Plunger and plunger housing stainless steel, seals made from Viton® |
Calibration gas valve | All brass, or to be specified. Plunger and plunger housing stainless steel, seals made from Viton® |
Sample pump | All stainless steel, diaphragm and valves made from Viton® |
Sample pump Capacity | 12 l/min, unrestricted flow |
Oven Temperature | 190°C (374°F), electronic temperature controller |
Oven Temperature Output | 0-5 VDC @ 10mV/°C |
Power Requirements | 230VAC/50Hz, 1250W (115VAC/60Hz, 850W) |
Ambient Temperature | 5-43°C (41-110°F) |
Available Options
EPC 11 | Remote control for sample pump. Pump can be switched on and off externally if Instrument is in external mode. |
APO 11 | Built in automatic programmable back-purge timer for the sample filter |
COS 11 | Overflow calibration system for EPA CFR 40, Method 25A |
TPR 11 | Built in temperature controller for J.U.M. heated sample lines Model TJ 100 and TJ 100A; EXTERNAL MODULE ONLY ON VE 112A! |
Attachments
Rugged transport case for mobile use (e.g. for mobile FTIR)
Jumatherm beheizter Probenahmeschlauch mit austauschbarer PTFE Innenseele
Robuster Trägerschlauch
Silicongummi Endkappen
Isolierung mit Filz und 7mm Siliconschaum
Außenschutzgeflecht Polyamid oder VA
Leistungsaufname 100W/m
Länge nach Wunsch (1 bis 35m oder länger in Sonderausführung)
Zugentlastungsseil unter den Siliconenschaum mitgeführt
Optionen
Feste oder austauschbare PTFE Seele
Zweite Seele z.b. als Kalibrationsleitung
Interne Steuerleitung
Durchmesser Innenseele 6mm, 8mm oder Größer
Zwei beheitzte Seelen statt einer
Edelstahl Einschraubstück als Knickschutz der Innenseele Ex-Schutz
Interne Leitung aus PFA statt PTFE
Rugged transport case for mobile use.
Datalogging
To log the 0-10V and/or 4...20mA analog outputs.
PC-powered: Over USB Software-based J.U.M. MhcLog-109 (dual channel)
Hand held battery powered: Ahlborn ALMEMO 2590
Die M&C Faltenbalgpumpen sind für die besonderen Anforderungen in der Analysentechnik ausgelegt. Die Pumpen sind dabei speziell zur Förderung korrosiver Gase geeignet.
Spezifische Merkmale
• Medium- korrosivgeschützte Materialien
• Schmierstofffreiheit zur Reinhaltung des geförderten Gases
• Wartungsfreie Konstruktion
• lange Standzeiten
• Sehr niedrige Wartungskosten
Die Pumpen weisen variable Anschlüsse auf – entweder seitlich oder oben auf dem Pumpenkopf. Die Pumpenkopfmontage kann beliebig in 90 Grad-Schritten erfolgen.Diese M&C-Neuprodukte sind ab sofort in 16 Versionen, 230 V oder 115 Volt sowie zwei Leistungsvarianten erhältlich. Weitere Varianten und Produktzulassungen hat M&C in Vorbereitung.Ein detailliertes Datenblatt und eine Betriebsanleitung stehen zur Verfügung. Weitere Vertiefungsinformationen sind abrufbar bei den technischen Beratern der M&C in Ratingen. Oder auch dem flächendeckenden M&C-Außendienst im gesamten deutschsprachigen Raum. Und natürlic
Heated FID analyser for TOC measurements.
TÜV approved for 2. BImSchV. 13. BImSchV and 17. BImSchV, fully complies with EN 12619, EN 13526 (EU) and EPA Method 25A and Method 503 (USA).
Features
- Maintenance free sample filter back purge system allows filter to be cleaned without dismantling (automatic optional)
- Built in burner air generator, no external air cylinder needed
- All components in contact with sample fully heated and controlled at 190 degree C
- Built-in sample pressure and sample pumps
- Automatic flame out alarm and contact
- Fast response within 1 second
- Low fuel consumption
- Very selective
- Microprocessor controlled PID-type temperature controller
- Remote control for sample, calibrate and back purge is standard
- Remote or automatic range change optional
Applications
- Stack gas hydrocarbon emissions monitoring
- Fence line monitoring
- Raw exhaust vehicle emissions analysis
- Catalytic converter testing
- Measuring engine combustion efficiency
- Hydrocarbon contamination monitoring in air and other gases
- Carbon adsorption regeneration control
- Detection of trace hydrocarbons in purity gases used in the semi conductor industry
- LEL monitor of solvent laden air
Attachments
Rugged transport case for mobile use. Front and back panel removable for easy access and operation.
Datalogging
To log the 0-10V and/or 4...20mA analog outputs.
PC-powered: Over USB Software-based J.U.M. MhcLog-109 (dual channel)
Hand held battery powered: Ahlborn ALMEMO 2590